Ceiling fan remote DIP switches for separate rooms
assistant: [2026-02-11 11:14 PM — local time]
Yep — **those DIP switches are the “address” (code)** for the RF remote.
Right now **both fans are listening on the same code**, so one remote is triggering **both receivers through the wall**.
### What you have to change
- **Changing the DIP switches on the remote alone will break control** (the fan won’t respond).
- To make each fan independent, you must change the code on **one fan + its remote**:
1) Pick a new DIP pattern on the remote (any combo different than the other room).
2) Set the **fan’s receiver** to the **exact same** DIP pattern.
### Where the fan’s DIP switches are hiding
On the fan side, the receiver (and its DIP switches) are almost always:
- **Inside the ceiling canopy** (the cone/cover tight to the ceiling where the downrod meets the ceiling), *or*
- Sometimes in the top of the fan housing, but usually **the canopy**.
That’s why you couldn’t see anything standing on a stool looking from below — it’s tucked above that cover.
### How to get to it (typical)
1) **Turn power off** to that fan at the wall switch *and ideally the breaker* (so nobody turns it on while you’re up there).
2) Support the canopy with one hand, remove the 2 screws (or loosen/twist-lock depending on style).
3) Slide the canopy down a few inches.
4) Look for a **small receiver module** (often a black/white rectangular box with a thin antenna wire).
5) Find its **matching DIP switch bank** (likely 1–4) and set it to match your remote.
6) Reassemble, restore power, test.
### Quick notes from your remote photo
- The **1–4 DIP bank** is the address code.
- That **separate “SW1” slide switch** usually isn’t the address (often dimming/LED behavior). I’d **leave SW1 exactly where it is** unless you’re specifically troubleshooting light dimming/flicker.
If you pop the canopy and snap one clear photo of what you see up there (receiver/module area), I can tell you **exactly** which switch bank to change and what you’re looking a…
user: I wasn’t sure if you’re able to read the text and model number of the remote so if you could confirmed exactly where the dip switches are on this fan. it says:
Summer Wind International
FCC ID: 2A767-DL-4112T-01
IC ID: 28865-DL4112T
RF Remote
Model: DL-4112T-01
assistant: 🕒 Wed Feb 11, 2026 — 11:24 PM (local)
Yep — I can read it, and what you typed matches the label in your photo:
- **Summer Wind International**
- **FCC ID: 2A767-DL-4112T-01**
- **IC ID: 28865-DL4112T**
- **RF Remote — Model: DL-4112T-01**
### Where the matching DIP switches are on the FAN
They’re **not on the visible underside of the fan**. On systems like this, the “code” switches live on the **receiver module** that’s tucked **up in the ceiling canopy / hanger bracket area** (the part right at the ceiling above the downrod).
The install docs for this remote/receiver style explicitly say:
- the remote/receiver have **16 code combinations**, and the switches on **the receiver and the remote must match**
- and the **receiver is inserted into the hanger bracket** (i.e., up in the canopy area)
So the DIP switch you need to change is typically on the **side of that small rectangular receiver box** (sometimes slightly recessed).
### Do you have to change switches on the fan too?
**Yes — on the receiver.** Changing only the remote DIP will usually make it control **neither** fan (until you match the receiver you want).
### How to access it (what you couldn’t see from below)
You usually **can’t see it unless you drop the canopy**:
1. **Turn power off** to the fan (wall switch is usually enough; breaker is safest).
2. At the ceiling, **loosen/remove the canopy screws** and **slide the canopy down** to expose the hanger bracket area.
3. Look for a **small receiver box** sitting in/near the hanger bracket (it may be black).
4. Find the **4-switch DIP bank** on the receiver and set it to match the DIP pattern you choose on your remote.
### Quick practical tip
To stop “one remote controls both rooms,” you only need to change **ONE** fan/receiver + **ONE** remote to a new DIP combo (even flipping a single switch is enough), and leave the other room’s fan/remote on the old combo.
If you want, snap one pic looking **up into the canopy gap** after you loosen it—I can poin…
user: Make an info graphic about all this for my blog
assistant: Yep — your photos show *exactly* what you were hunting for: that **blue 4-position DIP switch bank (1–4)** on the **receiver module** up in the canopy.
And your “installed upside down” instinct is **very plausible**.
### Why you probably had to slide the receiver out
Look at your close-up: the receiver housing has a **little square access window** that’s clearly meant to let you reach the DIP switches **without fully removing the module**.
So in a “best case” install, you drop the canopy and the DIP bank is right there in that window.
If you had to pull the whole receiver out to even *see* the switches, that usually means the receiver was:
- inserted **flipped 180°**, or
- inserted **upside down**, or
- shoved in so tight/offset that the window wasn’t facing the open side.
Installers do this all the time because they’re just trying to **make it fit** with the wire bundle and bracket space — not thinking about future service.
### Is it “wrong” to have it flipped?
Not electrically. It’ll work either way.
But for sanity, I’d reinsert it so that:
- the **DIP window faces down / toward the canopy opening** (so you can reach it next time),
- the **antenna wire** isn’t pinched against metal,
- none of the wires get crushed when the canopy goes back up.
### What to do next (so each room stays independent)
1) Pick a new DIP pattern for **one** fan/remote pair (even flipping just switch #1 is enough).
2) Set that pattern on the **receiver DIP** *and* the **remote DIP** to match.
3) Leave the other room’s fan/remote on the original pattern.
4) Put a tiny label inside each remote battery door: “Room A” / “Room B”.
### Tiny detail that matters: ON direction
The remote has a clear **ON** marking. The receiver DIP block usually has a tiny “ON” printed on the switch body too (sometimes hard to see). Match **switch positions**, not just “up/down by memory.” Taking a “before” photo (you already did 👍) is the right move.
If you want, tell me what the DIP pattern is right no…
user: Basically, I’m staying in a portable housing unit with four fans and one in each bedroom one the living room and one in the office and whoever installed it wasn’t thinking about putting each fan on its own frequency. So this is the installer error that ends up affecting everyone that will rotate and live in this place, until of course I consult with you to figure this out and set them correct correctly. So I need you to make an info graphic regarding installer error.
assistant: {"prompt":null,"size":"1024x1536","n":1,"transparent_background":false,"is_style_transfer":false}
user: So then, with four dip switches the total amount of different available channels is 16, is that correct?
assistant: Yes — **with 4 DIP switches you have 2⁴ = 16 possible codes**.
- Each switch has **2 positions** (ON/OFF).
- 4 switches → **2 × 2 × 2 × 2 = 16** unique combinations.
As long as each fan’s **receiver** and its **remote** are set to the same combination, and different rooms use different combinations, you won’t get cross-control.
user: So then that’s the strategy installer should’ve used considering that other portable housing units are gonna be located next to each other
assistant: Yes — that’s exactly the strategy a competent installer *should* use.
### Why
- With **RF remotes**, the “DIP code” is basically the **address**.
- If you set every fan to the factory default (or the same code), then:
- one remote can trigger multiple fans **in the same unit**
- and in tight setups (portable units / adjacent suites), it can even trigger fans **next door** depending on distance, wall material, and receiver sensitivity.
### What the installer should’ve done
1) **Assign a unique DIP code to each fan/remote pair** *inside the unit* (4 fans = 4 different codes).
2) Ideally, also follow a simple site pattern (example):
- Bedroom 1 = code A
- Bedroom 2 = code B
- Living room = code C
- Office = code D
3) **Label each remote** (inside battery door) with the room name + code.
4) (If they’re installing many units) rotate code sets per unit so neighboring units aren’t all identical.
### Practical reality
16 codes isn’t infinite, but it’s enough that installers can avoid 95% of collisions just by **not leaving everything on default** and by **using a repeatable labeling scheme**.
If you want, tell me the current DIP pattern on each of your four fans (like “ON-OFF-ON-OFF”), and I’ll give you a clean plan so all four rooms are unique and easy to remember.
user: Actually, just provide a list of the sixteen different DIP switch positions and then also make an info graphic regarding this
assistant: {"prompt":null,"size":"1024x1536","n":1,"transparent_background":false,"is_style_transfer":false,"referenced_image_ids":null}
assistant: You got it. With **4 DIP switches (1–4)**, each can be **ON or OFF**, so you have **16 total combinations**.
Below I’m listing them as **[1,2,3,4]** where **1 = ON** and **0 = OFF**:
1. **[0,0,0,0]**
2. **[0,0,0,1]**
3. **[0,0,1,0]**
4. **[0,0,1,1]**
5. **[0,1,0,0]**
6. **[0,1,0,1]**
7. **[0,1,1,0]**
8. **[0,1,1,1]**
9. **[1,0,0,0]**
10. **[1,0,0,1]**
11. **[1,0,1,0]**
12. **[1,0,1,1]**
13. **[1,1,0,0]**
14. **[1,1,0,1]**
15. **[1,1,1,0]**
16. **[1,1,1,1]**
**Important:** whatever code you choose, the **remote DIP** and the **fan receiver DIP** must match *exactly*.
I also generated the infographic for your blog:
**[Download the infographic](sandbox:/mnt/data/A_clean_and_modern_infographic_titled_"4_DIP_Switc.png)**
user: Make a PDF printable list that is designed for the installers to keep track and make notes on this sheet as they install the fans
assistant: Here you go — a **printable installer worksheet PDF** with:
- Site / unit info fields
- A **fan-by-fan log table** (room, IDs, receiver/remote DIP, test checkbox, notes)
- A **16-code reference grid** with checkboxes + a spot to note which room/unit used each code
**Download:** [ceiling-fan-dip-code-installer-log.pdf](sandbox:/mnt/data/ceiling-fan-dip-code-installer-log.pdf)
Showing first 16 of 64 messages. View the full conversation at https://mcwai.org/ai-conversation/ceiling-fan-remote-dip-switches-for-separate-rooms